Features & Benefits
-
TCA75 – TekConnect-to-75 Ω
BNC
- DC to ≥4 GHz (Instrument Dependent)
- VSWR
– 1.1:1 (26.45 dB)
- 75 Ω Input
- Auto Attenuation Factor
Correction
-
TCA-BNC – TekConnect-to-TekProbe™
BNC 50 Ω
- DC to ≥4 GHz (Instrument Dependent)
- 50 Ω Input (Only)
- Probe Control TekProbe BNC (50 Ω)
-
TCA-N – TekConnect-to-N
- DC to ≥11 GHz
(Instrument Dependent)
- 50 Ω Input (Only)
-
TCA-SMA – TekConnect-to-SMA
- DC to ≥18 GHz (Instrument
Dependent)
- 50 Ω Input (Only)
-
TCA-292MM
– TekConnect to 2.92 mm
- DC to ≥25 GHz (Instrument
Dependent)
- 50 Ω Input (Only)
- SMA Compatible
Applications
- Signal Integrity, Jitter,
and Timing Analysis
- Verification, Characterization, and Debug
of Sophisticated Designs
- High-speed Digital Devices and Circuits
- Power Supplies/Inverters
- Semiconductor Devices
- Electronic Ballasts
- Industrial/Consumer Electronics
- Mobile Communications
- Motor Drives
- Transportation
Systems
- Disk Drive Analysis
- Investigation of Transient
Phenomena
- Spectral Analysis
- Video Design and Development
- HDTV and Streaming Digital Video
TekConnect
Interface Delivers Superior Signal Fidelity, Unparalleled Versatility,
and Ease of Use
The TekConnect interface ensures superior
signal fidelity with useful bandpass up to 25 GHz, while offering
unparalleled versatility with the world's widest array of accessory
signal acquisition solutions for high-performance, real-time oscilloscopes.
This interface delivers a robust oscilloscope interface for next-generation
products with multi-GHz analog bandwidths. The TekConnect interface
preserves a low Voltage Standing Wave Ratio (VSWR) 50 Ω environment
as well as a reliable electrical connection. A convenient, one-button
release and locking mechanism provides quick, easy installation and
removal of probes, amplifiers, and adapters.
TekConnect TCA
Series Adapters Expand the Functionality of Tektronix High-performance
Oscilloscopes
This family of adapter systems provides less
signal distortion and better performance than traditional connections
used to move a signal from one environment to another, such as BNC
to N or BNC to SMA.
TCA75 Adapter (75 to 50 Ω)
The
TCA75 adapter allows Tektronix oscilloscopes with a TekConnect interface
to easily access and measure 75 Ω terminated circuitry. The TCA75
attenuation factor is automatically corrected to provide the end user
with correctly displayed signal magnitudes.
TCA-BNC Adapter
(50 Ω only)
A direct 50 Ω input with TekProbe BNC 50 Ω capability,
this adapter may be used as a direct 50 Ω BNC input or with Tektronix
high-speed active and differential probes requiring the TekProbe BNC
50 Ω interface.
TCA-SMA and TCA-N Adapters (50 Ω only)
The high-speed SMA- and N-type adapters allow a more direct connection
to the signal under test requiring N or SMA connections without losing
performance by adding other external conversion adapters.
TCA-292MM Adapter (50 Ω only)
The high-speed 2.92 mm-type
adapter allows a more direct connection to the signal under test requiring
a 2.92 mm connection without losing performance by adding other external
conversion adapters. The locking screw must be used to ensure full
bandwidth performance. The 2.92 mm connector is more robust and performs
at higher frequencies than an SMA connector. The 2.92 mm connector
is compatible with SMA connectors, but the electrical performance
will be limited to the bandwidth of the SMA connector.