Recommended Test Equipment for DisplayPort Compliance Testing per Compliance Test Specification 1.1 (CTS)
DisplayPort Source Test
| Product | Description | Quantity |
| Oscilloscope | Real-time DPO/DSA70804B or higher and Opt. 5XL*1 | 1 |
| Analysis Software | DPOJET Jitter and Eye Diagram Analysis Tool Option DJA | 1 each |
| Compliance Software | DPO DPT DisplayPort Compliance Test Solution Option DSPT | 1 each |
| SMA Probe | P7380SMA Differential Probe | 4 each |
| Test Fixtures | ET-DP-TPA-STX | 1 each |
| Controller | DisplayPort Auxilary Channel Controller (DP-AUX) | 1 each |
| Accessories | Terminators P/N: 015-1022-01 | 8 each |
DisplayPort Sink Test
| Product | Description | Quantity |
| High Speed Signal Source | AWG7122B Arbitrary Waveform Generator with Options 1, 6, 8 or AWG7102B with Options 1, 6 |
1 |
| Oscilloscope*2 | Real-time DPO/DSA70804B or higher and Opt. 5XL*1 | 1 |
| Software | SerialXpress® (SDX100) Advanced Jitter Generation Tool with Options ISI and SSC DPOJET Jitter and Eye Diagram Analysis Tool with Option DJA TekExpress Sink Compliance Tool with Option TEKEXP DP-SINK |
1 each |
| Test Fixtures | ET-DP-TPA-S | 1 each |
| Controller | DisplayPort Auxilary Channel Controller (DP-AUX) | 1 each |
| Attenuators *7 | 14 dB P/N: 015-1002-01 6 dB P/N: 015-1001-01 |
4 6 |
| Accessories | Picosecond Pulse Lab Filter
P/N: 5915-110-100ps*3 Picosecond Pulse Lab DC Block P/N: 5501A*4 Phase Matched SMA Cable Set P/N: 174-4944-01 SMA Cables P/N: 174-1341-00 Terminators P/N: 015-1022-01 |
4 each 2 each 2 each 4 each 20 each |
DisplayPort Cable Test: Passive Cables*5
| Product | Description | Quantity |
| Oscilloscope | DSA8200 Sampling Oscilloscope | 1 |
| Module for Oscilloscope | 80E04 TDR Module | 4*5 |
| Software | 80SSPAR Iconnect TDR and S-Parameter Software | 1 |
| Test Fixtures/Accessories | ET-DP-TPA-S Female-to-Female SMA Adapter P/N: 015-1012-00 Phase Matched SMA Cable Set P/N: 174-4944-01 |
1 set 4 each 4 each |
DisplayPort Cable Test: Active Cables*6
| Product | Description | Quantity |
| Oscilloscope | DSA8200 Sampling Oscilloscope | 1 |
| Modules for Oscilloscope | 80E04 TDR Module and 80A06 Pattern Sync Module | 1 each |
| High Speed Signal Source | AWG7122B Arbitrary Waveform Generator with Options 1, 6, 8 or AWG7102B with Options 1, 6 |
1 |
| Software | 80SJNB Jitter Analysis and 80SSPAR Iconnect TDR and S-Parameter Software | 1 each |
| Test Fixtures | ET-DP-TPA-S | 1 set |
*1 Opt. 5XL required for Tests 3-11 Non ISI Jitter and 3-12 Total Jitter Measurements if also used for source testing.
*2 RT oscilloscope is used for jitter calibration and eye diagrams in receiver (Sink) tests.
*3 Rise time filters required to provide typical operating edge rates for adjacent lanes.
*4 DisplayPort requires source AC coupling.
*5 Two 80E04 modules can be used for the manual testing, but four are recommended for the automated method.
*6 MOIs available at www.tektronix.com/displayport. www.tektronix.com/displayport
*7 If testing tethered devices, two 20 dB attenuators (011-0059-03) are required in addition to attenuators listed above.