DCSIMG
Tektronix » Applications » Serial Data » Displayport » DisplayPort Source Test Recommended Equipment

Recommended Test Equipment for DisplayPort Compliance Testing per Compliance Test Specification 1.1 (CTS)

DisplayPort Source Test

Product Description Quantity
Oscilloscope Real-time DPO/DSA70804B or higher and Opt. 5XL*1 1
Analysis Software DPOJET Jitter and Eye Diagram Analysis Tool Option DJA 1 each
Compliance Software DPO DPT DisplayPort Compliance Test Solution Option DSPT 1 each
SMA Probe P7380SMA Differential Probe 4 each
Test Fixtures ET-DP-TPA-STX 1 each
Controller DisplayPort Auxilary Channel Controller (DP-AUX) 1 each
Accessories Terminators P/N: 015-1022-01 8 each

DisplayPort Sink Test

Product Description Quantity
High Speed Signal Source AWG7122B Arbitrary Waveform Generator with Options 1, 6, 8 or
AWG7102B with Options 1, 6
1
Oscilloscope*2 Real-time DPO/DSA70804B or higher and Opt. 5XL*1 1
Software SerialXpress® (SDX100) Advanced Jitter Generation Tool with Options ISI and SSC
DPOJET Jitter and Eye Diagram Analysis Tool with Option DJA
TekExpress Sink Compliance Tool with Option TEKEXP DP-SINK
1 each
Test Fixtures ET-DP-TPA-S 1 each
Controller DisplayPort Auxilary Channel Controller (DP-AUX) 1 each
Attenuators *7 14 dB P/N: 015-1002-01
6 dB P/N: 015-1001-01
4
6
Accessories Picosecond Pulse Lab Filter P/N: 5915-110-100ps*3
Picosecond Pulse Lab DC Block P/N: 5501A*4
Phase Matched SMA Cable Set P/N: 174-4944-01
SMA Cables P/N: 174-1341-00
Terminators P/N: 015-1022-01
4 each
2 each
2 each
4 each
20 each

DisplayPort Cable Test: Passive Cables*5

Product Description Quantity
Oscilloscope DSA8200 Sampling Oscilloscope 1
Module for Oscilloscope 80E04 TDR Module 4*5
Software 80SSPAR Iconnect TDR and S-Parameter Software 1
Test Fixtures/Accessories ET-DP-TPA-S
Female-to-Female SMA Adapter P/N: 015-1012-00
Phase Matched SMA Cable Set P/N: 174-4944-01
1 set
4 each
4 each

DisplayPort Cable Test: Active Cables*6

Product Description Quantity
Oscilloscope DSA8200 Sampling Oscilloscope 1
Modules for Oscilloscope 80E04 TDR Module and 80A06 Pattern Sync Module 1 each
High Speed Signal Source AWG7122B Arbitrary Waveform Generator with Options 1, 6, 8 or
AWG7102B with Options 1, 6
1
Software 80SJNB Jitter Analysis and 80SSPAR Iconnect TDR and S-Parameter Software 1 each
Test Fixtures ET-DP-TPA-S 1 set

*1 Opt. 5XL required for Tests 3-11 Non ISI Jitter and 3-12 Total Jitter Measurements if also used for source testing.
*2 RT oscilloscope is used for jitter calibration and eye diagrams in receiver (Sink) tests.
*3 Rise time filters required to provide typical operating edge rates for adjacent lanes.
*4 DisplayPort requires source AC coupling.
*5 Two 80E04 modules can be used for the manual testing, but four are recommended for the automated method.
*6 MOIs available at www.tektronix.com/displayport. www.tektronix.com/displayport
*7 If testing tethered devices, two 20 dB attenuators (011-0059-03) are required in addition to attenuators listed above.