Recommended Test Equipment for DisplayPort Compliance Testing per Compliance Test Specification 1.1 (CTS)
DisplayPort Source Test | DisplayPort Sink Test | DisplayPort Cable Test
DisplayPort Source Test
| Product | Description | Quantity |
| Oscilloscope | Tektronix Real-time DPO/DSA70804 or higher and Opt. 5XL1 | 1 |
| Software | DPOJET Jitter and Eye Diagram Analysis Tool; DPO-DSPT DisplayPort Automated Compliance Testing | 1 each |
| SMA Probe | P7380SMA or P7313SMA Differential Probes | 4 each |
| Test Fixtures | ET-DP-TPA-STX | 1 |
1 Opt. 5XL required for Tests 3-11 Non ISI Jitter and 3-12 Total Jitter Measurements
DisplayPort Sink Test
| Product | Description | Quantity |
| High Speed Signal Source | AWG7102 with Opt 01 and 06 | 1 |
| Oscilloscope 1 | Tektronix Real Time DPO/DSA70804 or higher and Opt. 5XL2 | 1 |
| Software | DPOJET Jitter and Eye Diagram Analysis Tool; SerialXpress(R) Advanced Jitter Generation Tool with Opt ISI | 1 each |
| Test Fixtures | ET-DP-TPA-S | 1 |
| Attenuators (14dB) | Tek P/N: 015-1002-01 | 6 each |
| Attenuators (6dB) | Tek P/N: 015-1001-01 | 4 each |
| DC Block - Picosecond Pulse Lab | 5501A-1104 | 2 (for analog output) |
| Rise Time Filter3 - Picosecond Pulse Lab | 5915-110-100 ps | 4 each |
1 Oscilloscope required for jitter calibration process.
2 Opt. 5XL required for Tests 3-11 Non ISI Jitter and 3-12 Total Jitter Measurements
3 Rise time filters required to provide typical operating edge rate for adjacent lanes.
4 DisplayPort requires source AC coupling.
DisplayPort Cable Test
Recommended Equipment for Passive Cables
| Product | Description | Quantity |
| Sampling Oscilloscope | DSA8200 | 1 |
| TDR Module for Sampling Oscilloscope | 80E04 TDR Sampling Module for DSA8200 | 4 each5 |
| Iconnect TDR and S-Parameter Software | 80SSPAR | 1 |
| Test Fixtures | ET-DP-TPA-S | 1 |
| SMA | Female-to-female Adapter | 4 each |
5 Two 80E04 modules can be used for manual testing but four are recommended for the automated method.
Recommended Equipment for Active Cables
| Product | Description | Quantity |
| Sampling Oscilloscope | DSA8200 | 1 |
| Modules for Sampling Oscilloscope | 80E04 TDR Sampling Module; 80A06 Pattern Sync Module | 1 each |
| High Speed Signal Source | AWG7102 with Opt 01 and 06 | 2 each |
| Test Fixtures | ET-DP-TPA-S | 1 set |
| Iconnect TDR and S-Parameter Software | 80SSPAR | 1 |