Real-time Spectrum Analyzer
3026
This product is discontinued. View alternative products.
Check product support status.
Characteristics
Frequency Related
Frequency Range -
RF Mode: 10 MHz to 3 GHz.
Baseband Mode: 50 Hz to 10 MHz.
Frequency Span -
RF Mode: 100 Hz to 3 GHz.
Baseband Mode: 100 Hz to 10 MHz.
Stability of Frequency Standard - ± 5 x 10-9/day.
Residual FM - 3 Hz max.
Spectrum Purity - -100 dBc/Hz (10 kHz offset).
Center Frequency Settability - 0.1 Hz.
Amplitude Related
Reference Level Range -
RF mode: -50 to +30 dBm.
Baseband Mode: -30 to +30 dBm.
Input Impedance - 50 Ohm.
Input VSWR - <1.5 (at reference level >-20 dBm).
Maximum Nondestructive Input Voltage - +30 dBm.
Internal Gain - ±1.0 dBm at 25 MHz.
Flatness -
±2.0 dB (>500 Hz).
+2.0, -5.0 dB (<500 Hz).
Input Equivalent Noise - -140 dBm/Hz at 1 GHz.
2nd Harmonic Distortion - <-70 dBc (-10 dBfs input level).
3rd Order Distortion -
<-60 dBc (<20 MHz, <-10 dBfs input).
<-70 dBc (<20 MHz, <-10 dBfs input).
Spurious Response -
<-65 dBc (<400 kHz offset).
<-70 dBc (>400 kHz offset).
Residual Response -
<-40 dBfs (50 Hz +10 bin).
<-65 dBfs (>center ±2 bin).
<-70 dBfs (>exclude above).
Image Suppress - -70 dB.
A/D Converter - 12-Bits, 25.6 MS/s.
Input Anti-aliasing Filter -
±0.3 dB (<10 MHz).
-60 dB (>15.5 MHz).
Frame Time Related
FFT Points - 1024, 256.
FFT Window - Blackman-Harris, Hamming, Rectangle.
Operation Accuracy - 16-Bit, Block-Floating.
Maximum Overlapping at 1024 FFT Point -
512 point at 5 MHz.
768 point at 2 MHz span.
896 point at 1 MHz.
960 point at 500 kHz span.
960 point at 200/20/2 kHz span.
992 point at 100/10/1 kHz span.
1008 point at 50/5 kHz span.
1008 point at 500/200/100 Hz span.
Maximum Overlapping at 256 FFT Point -
192 point at 2 MHz.
224 point at 1 MHz.
240 point at 500 kHz span.
192 point at 200/20/2 kHz span.
224 point at 100/10/1 kHz span.
240 point at 50/5 kHz span.
240 point at 500/200/100 Hz span.
Decimation Filter Related
Filter Type -
5 MHz span: 134-tap FIR Filter.
2 MHz span: 201-tap FIR Filter.
1 MHz span: 268-tap FIR Filter.
500 kHz span: 317-tap FIR Filter.
200 kHz span: 391-tap FIR Filter.
100 kHz span: 503-tap FIR Filter.
50 kHz span: 503-tap FIR Filter with 4-stage Comb Filter.
10 kHz span: 503-tap FIR Filter with 4-stage Comb Filter.
5 kHz span: 459-tap FIR Filter with 4-stage Comb Filter.
2 kHz span: 503-tap FIR Filter with 4-stage Comb Filter.
1 kHz span: 459-tap FIR Filter with 4-stage Comb Filter.
500 Hz span: 459-tap FIR Filter with 4-stage Comb Filter.
200 kHz span: 459-tap FIR Filter with 4-stage Comb Filter.
100 kHz span: 503-tap FIR Filter with 4-stage Comb Filter.
Word Length FIR Filter Coefficient - 20-Bit.
Stopband Attenuation - 90 dB.
Passband Ripple - 0.2 dB.
Minimum Frame Update Rate
| Span |
1024 point |
512 point |
| 500 kHz to 5 MHz |
16 µs |
|
| 500 kHz to 2 MHz |
|
40 µ |
| 50 kHz to 200 kHz |
400 µs |
400 µs |
| 5 kHz to 20 kHz |
4 ms |
4 ms |
| 500 Hz to 2 kHz |
40 ms |
40 ms |
| 200 Hz |
100 ms |
100 ms |
| 100 Hz |
200 ms |
200 ms |
Real Time Span - < 2 MHz.
Trigger Related
Trigger Mode - Auto/Normal (Frequency and Time Events).
Trigger Source - Internal/External.
Internal Trigger Level -
Max: 0 dBfs.
Min: -55 dBfs.
Level Resolution of Internal Trigger - 19-Bit.
Frequency Resolution of Internal Trigger -
Span/800: 5 MHz span, 1024 point FFT.
Span/640: 2 MHz span, 1024 point FFT.
Span/160: 256 point FFT.
Time Resolution of Internal Trigger - Same as the interval of spectrum frame update.
External Trigger Level - 1.6 V ±0.2 V.
Voltage Range of External Trigger Input - 0 to 5 V.
Acquire Mode - Block/Roll.
Maximum Block Length -
1,000 frames (1024 point FFT).
4,000 frames (256 point FFT).
Roll Mode Update Rate - 10 frame/sec.
Acquisition Related
The 3026 offers a full 2 MHz of real-time bandwidth with measurement speed of 25,000 frames/second and a 1024 point update interval of 160 microseconds.
System Controller
486DX4-100 (100 MHz Clock), 32 MB 60 ns fast page SIMM (nonparity), 2.5 in. 3 MB solid state drive, 2.5 in. 2.1 GB hard disk, 3.5 in. 2 HD (1.44 MB) floppy disk, on board Ethernet LAN I/F, ISA half size GPIB.
Environmental
Temperature -
Operating: +10°C to 40°C.
Nonoperating: -20°C to +60°C.
Temperature Gradient -
Operating: <5 per hour (no condensation).
Nonoperating: <30 per hour (no condensation).
Relative Humidity -
Operating: 20% to 80% (no condensation). Maximum wet-bulb temperature 29.4.
Nonoperating: 5% to 90% (no condensation). Maximum wet-bulb temperature 40.0.
Altitude -
Operating: up to 4.5 km (15,000 ft). Maximum operating temperature decreases 1 each 300 m above 1.5 km.
Nonoperating: Up to 15 km (50,000 ft).
Vibration -
Operating: 0.27 GRMS, 5 Hz to 500 Hz.
Nonoperating: 2.28 GRMS, 5 Hz to 500 Hz.
Shock -
Nonoperating: 294 m/s (30 G), half-sine, 11 ms duration. Three shocks per axis in each direction (18 shocks total).
Bench Handling -
Operating: drop from 10 cm (4") tilt, or 45° which ever less (tilt not to balance to point).
EMC Compliance
Emissions -
Enclosure: EN 55011 class A limits for radiated emissions.
AC Main: EN 55011 class A limits for conducted emissions. EN 61000-3-2 power line harmonics.
Immunity -
Enclosure: EN 61000-4-2 electrostatic discharge immunity. EN 61000-4-3 RF electromagnetic field immunity.
AC Main: EN 61000-4-4 electrical fast transient immunity. EN 61000-4-5 Surge. EN 61000-4-6 conducted disturbance induced by radio-frequency field. EN 61000-4-8 power frequency electromagnetic field. EN 61000-4-11 power line interruption immunity.
Power
Line Voltage Range - 90 to 250 VAC.
Line Frequency - 48 to 63 Hz.
Maximum Power - 300 W.
Maximum Current - 4 A.
Fuse Rating - 6 A, 250 V, Fast blow.
Grounding Impedance - Verify continuity of grounding connection by any suitable means between a representative part required to be grounded and the attachment-plug cap grounding pin (0.1 Ohm at 30 A).
Primary Circuit Dielectric Voltage Withstand Test - 1500 VRMS, 50 Hz for 15 seconds, without breakdown.
Physical Characteristics
| Dimensions |
mm |
in. |
| Height |
165 |
6.5 |
| Width |
376 |
14.8 |
| Depth |
495 |
19.5 |
| Weight |
kg |
lb. |
| Net |
13 |
29 |
Warranty
One year parts and labor.
Safety
UL3111-1, CSA231, EN61010-1, IEC61010-1.
Self-declaration - EN61010-1 with second amendment.
For more comprehensive and environmental specifications, please see the Tektronix website. |